Experimental Study of Timber-Steel Arch with the Support Joints on Glued-in Steel Rods

Authors:

Dmitry D. Koroteev,Farid A. Boytemirov,Makhmud Kharun,

DOI NO:

https://doi.org/10.26782/jmcms.2019.03.00029

Keywords:

Timber-Steel Arch, Corrosion Resistance ,Fire Resistance ,Bearing Capacity, Steel Rods,

Abstract

Vital problem, occurring in the operation process of bearing timber structures, is improvement of their durability in conditions of aggressive environment. Another aspect of this problem is the increase of fire resistance of timber-steel structures. One of the possible design solutions of this problem is given in the research work. The aim of the research is study of experimental arch with support joints on glued-in steel rods. The arch was developed based on typical timber-steel arch with span length 11.8 m. Geometric shape and sizes of the arch were kept without changes, but steel elements were replaced by timber elements. Design features of the arch and calculation methods, taking into account bearing capacity of the joints on glued-in steel rods, are given in the research work. The experimental arch showed enough reliability during the test and stiffness during transportation and mounting. The arch loading was carried out in laboratory bench by using hydraulic jacks. The load increased until the arch destruction. Deflection and deformation of glued-in steel rods were measured during the test. Information about vertical deformation in the arch and stretching tensions along the length of the rods under the load were obtained in the test results. The results show that shear tensions in the joints spread along the bonding length unevenly and they have maximum value on the surface of timber elements. The arch showed perceptivity of practical using in the mild chemical-aggressive conditions and bearing structures with high requirements of fire resistance.

Refference:

I.Asdrubali F., Ferracuti B., Lombardi L., Guattari C., Evangelisti L., Grazieschi G., (2017).A review of structural, thermo-physical, acoustical, and environmental properties of wooden materials for building applications. Building and Environment, 114: 307-332.

II.Audebert M., Dhima D., Taazount M., Bouchair A. (2011).Numerical investigations on the thermo-mechanical behavior of steel-to-timber joints exposed to fire. Engineering Structures, 33(12): 3257-3268.

III.Barber D. (2017).Determination of fire resistance ratings for glulam connectors within US high rise timber buildings. Fire Safety Journal, 91: 579-585.

IV.Bradford M.A., Hassanieh A.,Valipour H.R., Foster S.J. (2017).Sustainable Steel-timber Joints for Framed Structures. Procedia Engineering, 172: 2-12.

V.Cavalli A., Malavolti M., Morosini A., Salvini A., Togni M. (2014).Mechanical performance of full scale steel-timber epoxy joints after exposure to extreme environmental conditions. International Journal of Adhesion and Adhesives, 54: 86-92.

VI.Cheung K.C.K. (2016).Wooden Structures. Reference Module in Materials Science and Materials Engineering, USA.VII.Custodio J., Broughton J., Cruz H.(2009).A review of factors influencing the durability of structural bonded timber joints. International Journal of Adhesion and Adhesives, 29(2): 173-185.

VIII.De Luca V., Marano C. (2012).Prestressed glulam timbers reinforced with steel bars. Constructionand Building Materials, 30: 206-217.

IX.Di Maria V., D’Andria L., Muciaccia G., Ianakiev A. (2017).Influence of elevated temperature on glued-in steel rods for timber elements. Construction and Building Materials,147: 457-465.

X.Dietsch P. (2011).Robustness oflarge-span timber roof structures -Structural aspects. Engineering Structures, 33(11): 3106-3112.XI.Erchinger C., Frangi A., Fontana M. (2010).Fire design of steel-to-timber dowelled connections. Engineering Structures, 32(2): 580-589.
XII.Gattesco N., GubanaA., Buttazzi M., Melotto M. (2017).Experimental investigation on the behavior of glued-in rod joints in timber beams subjected to monotonic and cyclic loading. Engineering Structures, 147: 372-384.
XIII.Gonzales E., Tannert T., Vallee T. (2016).The impact ofdefects on the capacity of timber joints with glued-in rods. International Journal of Adhesion and Adhesives, 65: 33-40.
XIV.Koroteev D.D., Boytemirov F.A., Stashevskaya N.A. (2017).The strength research of the adhesive joints of sheet structures. Journal ofFundamental and Applied Sciences, 9(7S): 414-424.
XV.Li Z., Dong H., Wang X., He M. (2017).Experimental and numerical investigations into seismic performance of timber-steel hybrid structure with supplemental dampers. Engineering Structures, 151: 33-43.
XVI.Loss C., Piazza M., Zandonini R. (2016).Connections for steel–timber hybrid prefabricated buildings. Part I: Experimental tests. Construction and Building Materials, 122: 781-795.
XVII.Reynolds T., Harris R., Chang W. (2014).Nonlinear pre-yield modal properties of timber structures with large-diameter steel dowel connections. Engineering Structures, 76: 235-244.
XVIII.Sandhaas C., van de Kuilen J.G. (2017).Strength and stiffness of timber joints with very high strength steel dowels. Engineering Structures, 131: 394-404.
XIX.Steiger R., Serrano E., Stepinac M., Rajcic V., O’Neill C., McPolin D., Widmann R. (2015).Strengthening of timber structures with glued-in rods. Construction and Building Materials, 97: 90-105.
XX.Yeboah D., Taylor S., McPolin D., Gilfillan R., Gilbert S. (2011).Behaviour of joints with bonded-in steel bars loaded parallel to the grain of timber elements. Construction and Building Materials, 25(5): 2312-2317.
View | Download