EXPERIMENTAL STUDIES OF WELDED JOINTS OF PRECAST BUILDINGS FOR SHEAR AND TORSION

Authors:

Valery Lyublinskiy,Vladislav Struchkov,

DOI NO:

https://doi.org/10.26782/jmcms.2024.08.00001

Keywords:

Welded joints,Shear bonds,Torsion,Panel buildings,Stress-strain state,

Abstract

The spatial rigidity and strength of precast multi-story buildings are largely determined by the rigidity of the shear bonds connecting the vertical load-bearing reinforced concrete structures. When a horizontal load is applied in asymmetrical in-plan load-bearing systems of multi-story buildings, torsion occurs. In vertical shear bonds, especially those located furthest from the center of rigidity, a torque appears. This article presents the results of experimental studies of welded joints of precast buildings under the action of shear and torsion. The research study has been conducted using full-scale samples of shear bonds. The samples have been loaded with a static load vertical shear force and horizontal torsion moment. Various loading conditions are considered. Deformation diagrams of shear bonds were obtained. The limit state of a welded joint under shear and shear with torsion is described. The obtained experimental data on the rigidity of shear connections can be used in mathematical models for determining the stress-strain state of load-bearing systems of panel multi-story buildings.

Refference:

I. Ajay T., Parthasarathi N., Prakash M., : ‘Effect of planar irregularity of linear static and dynamic analysis’. Materials Today: Proceedings. Vol. 40, 2020. 10.1016/j.matpr.2020.03.499
II. Benaied B., Hemsas M., Benanane A., Hentri M., : ‘Seismic analysis of RC building frames with vertical mass and stiffness irregularities using adaptive pushover analysis’. Revista De La Construcción. Vol. 22(3), pp. 597–612, 2023. 10.7764/RDLC.22.2.597
III. Benavent-Climent A., Morillas L., Escolano-Margarit D., : ‘Inelastic torsional seismic response of nominally symmetric reinforced concrete frame structures: Shaking table tests’. Engineering Structures. Vol. 80, pp. 109–117, 2014. 10.1016/j.engstruct.2014.08.047
IV. Botis M., Cerbu С. A., : ‘Method for Reducing of the Overall Torsion for Reinforced Concrete Multi-Storey Irregular Structures’. Applied Sciences. Vol. 10, 5555, 2020. 10.3390/app10165555
V. De Stefano M., Pintucchi B., :‘A review of research on seismic behaviour of irregular building structures since 2002’. Bull Earthquake Eng. Vol. 6, pp. 285–308, 2008. 0.1007/s10518-007-9052-3
VI. Drozdov P., : ‘Design and Calculation of Load-bearing Systems of Multistorey Buildings and their Elements’. Moscow. Stroyizdat, 1977.
VII. Hussein G., Eid N., Khaled H., : ‘Torsional Behavior of Irregular Structures during Earthquakes’. Journal of Mechanical and Civil Engineering. Vol. 16, pp. 40-55, 2019. 10.9790/1684-1605044055
VIII. Karyakin A.A., Derbentsev I.S., Tarasov M.V., : ‘Experimental and Numerical Research on Tensile Performance of Inter-Panel Fastener Joints of Large-Panel Buildings’. IOP Conf. Ser.: Mater. Sci. Eng. Vol. 262, 2017. 10.1088/1757-899X/262/1/012046
IX. Khatiwada P., Lumantarna E., : ‘Simplified Method of Determining Torsional Stability of the Multi-Storey Reinforced Concrete Buildings’. Civil Eng. Vol. 2, pp. 290–308, 2021. 10.3390/civileng2020016
X. Lim H., Kang J. W., Pak H., Chi H., Lee Y. and Kim J., : ‘Seismic Response of a Three-Dimensional Asymmetric Multi-Storey Reinforced Concrete Structure’. Applied Sciences. Vol. 8(4), 479, 2018. 10.3390/app8040479
XI. Lyublinskiy V., Struchkov V., : ‘Resistance of Vertical Joints During Torsion of Multistorey Buildings’, Proceedings of FORM 2022, LNCE, Springer. Vol. 282, pp. 407-415, 2023. 10.1007/978-3-031-10853-2_38
XII. Lyublinskiy V.A., : ‘To the question of redistribution of stress in Vertical bearing rc structures multi-story buildings’. Building structures. Vol. 2 (94), pp. 39-45, 2021. 10.33979/2073-7416-2021-94-2-39-45
XIII. Lyublinskiy V.A., Tomina M.V., : ‘Experimental study of the strength and suppleness of a vertical welded joint’. Syst. Meth.Techn. Vol. 3(39), pp. 154-158, 2018. 10.18324/2077-5415-2018-3-154-158
XIV. Manual for the calculation of large-panel buildings Issue 1 Characteristics of the rigidity of walls, elements and joints of large-panel buildings. Moscow. Stroyizdat, 1974.
XV. Nabila Rossley, Farah Nora Aznieta Abdul Aziz, Heng Chiang Chew, Nima Farzadnia., : ‘Behaviour of vertical loop bar connection in precast wall subjected to shear load’. Aust. J. Basic & Appl. Sci. Vol. 8(1), pp. 370-380, 2014.
XVI. Naresh kumar B. G., Punith N., Bhyrav R.B., Arpitha T. P., : ‘Assessment of Location of Centre of Mass and Centre of Rigidity for Different Setback Buildings’. International Journal of Engineering Research & Technology. Vol. 6, Issue 5, pp. 801-804, 2017. 10.17577/IJERTV6IS050488
XVII. Negro P., Mola E., Molina F.J., Magonette G., : ‘Full-scale PsD testing of a torsionally unbalanced three-storey non-seismic RC frame’. Proceedings of 13th world conference on earthquake engineering, Vancouver, Canada; 2004.
XVIII. Satheesh A.J., Jayalekshmi B.R., Venkataramana Ka., : ‘Effect of in-plan eccentricity on vertically stiffness irregular buildings under earthquake loading’. Soil Dynamics and Earthquake Engineering. Vol. 137, 106251, 2020. 10.1016/j.soildyn.2020.106251
XIX. Sharma J., Singh A., Sehgal R., : ‘Torsional Reduction Techniques in High Rise Structures’. International Journal of Engineering Research & Technology (IJERT). Vol. 3, Issue 10, 2015. 10.17577/IJERTCONV3IS10013
XX. Shen S.D., Pan P., Miao Q.S., Li W.F., Gong R.H., : ‘Test and analysis of reinforced concrete (RC) precast shear wall assembled using steel shear key (SSK)’. Earthq. Eng. Struct. Dyn. Vol. 48, pp. 1595–1612, 2019. 10.1002/eqe.3215
XXI. Shuvalov A., Gorbunov I., Kovalev M., Faizova A., : ‘Experimental studies of compliance of vertical joints used in construction of high-rise panel buildings’, MATEC Web of Conferences, Vol. 196, 02049, 2018. 10.1051/matecconf/201819602049
XXII. Singhal S., Chourasia A., Chellappa S., Parashar J., : ‘Precast reinforced concrete shear walls: State of the art review’. Struct. Concr. Vol. 20, pp. 886–898, 2019. 10.1002/suco.201800129
XXIII. Sritharan S., Aaleti S., Henry R.S., Liu K.Y., Tsai K.C., : ‘Precast concrete wall with end columns (PreWEC) for earthquake resistant design’. Earthq. Eng. Struct. Dyn. Vol. 44, pp. 2075–2092, 2015. 10.1002/eqe.2576
XXIV. Yang, J.; Yang, Y.; Deng, L.; Sun, B.; Gu, Z.; Zeng, L.; Zhao, S., : ‘Seismic Behaviors of Prefabricated Reinforced Concrete Shear Walls Assembled with a Cast-in-Place Vertical Joint’. Buildings. Vol. 13, 2023. 10.3390/buildings13123013

View Download