An application of Z-N Tuning method with PID controller to optimize the system performance of cardiac muscle modeland it’s practical implementation using OP AMP

Authors:

Aishwarya Banerjee,Soumyendu Bhattacharjee,Biswarup Neogi,

DOI NO:

https://doi.org/10.26782/jmcms.2019.06.00023

Keywords:

PID controller, Addition of pole,Z-N tuning rule,Op-Amp.,

Abstract

The control system consisting different components mainly regulates, manages as well as senses the behavior of another system and gives the desired output. The properly tuned controllers are used widely in different industrial applications. This paper concentrates on the work based on the PID tuning by applying Z-N rule to get the optimized performance of control system based modeling of human cardiac muscle. The another aim of this paper is the addition of pole at origin in plant along with PID controller to increase the type of open loop transfer function of plant as steady state error for any input test signal reduces with the increment of type of a system. Due to addition of pole, transient part may get deteriorated as order increases with the increment of type of plant. To balance this fact, a proper PID controller has been introduced and designed by applying Z-N tuning rule to get an output with better dynamic and static performance of the total system. At the end of this work an OP-Amp based practical implementation of PID controller has been done to calculate the controller parameters in terms of resistance and capacitance for real life application.

Refference:

I.Ang, K.H., Chong, G.C.Y., and Li, Y. (2005). PID control system analysis, design, and technology, IEEE Trans Control Systems Tech, 13(4), pp.559-576.
II.Bouallegue S, Haggege J, Ayadi M, Benrejeb M. “ID-type fuzzy logic controller tuning based on particle swarm optimization”; Vol.25 (3), pp. 484–93, 2012.
III.http://www.cds.caltech.edu/~murray/courses/cds101/fa02/caltech/astr om-ch6.pdf.
IV. K. Astrom and T. Hagglund, “The future of PID control,” Control Engineering Practice, vol. no. 11, pp. 1163 – 1175.
V. Liang Taonian, Chen Jianjun, Lei Chuang. “Algorithm of robust stability region for interval plant with time delay using fractional order PIkDl controller”. J Commun Nonlinear Sci Numer Simul Vol.17(2), pp.979–91, 2012.
VI.Luo Ying, Chen Yang Quan. “Stabilizing and robust fractional order PI controller synthesis for first order plus time delay systems”. J Automatica; Vol. 48(9): pp. 2159–67, 2012.
VII.M.J. Mahmoodabadi, H. Jahanshahi, “Multi-objective optimized fuzzy-PID controllers for Fourthorder nonlinear systems”,Engineering Science and Technology, an International, Journal, Vol.19 pp.1084–1098, 2016.
VIII.M. Sahib, “A novel optimal PID plus second order derivative controller for AVR system”, Eng. Sci. Technol. Int. J. Vol.18, pp. 194–206, 2015.
IX.Norbert Hohenbichler. “All stabilizing PID controllers for time delay systems”; Vol. 45(11): pp.2678–84, 2009.
X.Ogata, K., Third ed, Modern Control Engineering, Prentice-Hall Inc,1997.
XI.OzbayHitay, Bonnet Catherine, Fioravanti Andre Ricardo. “PID controller design for fractional-order systems with time delays”.SystContr Lett; Vol.61(1): pp.18–23, 2012.
XII.Shabib G. “Implementation of a discrete fuzzy PID excitation controller for power system damping”. Ain Shams Eng J; Vol. 3(2): pp.123–31, 2012.
XIII.Suji Prasad SJ, Varghese Susan, Balakrishnan PA. “Particle swarm optimized pid controller for second order time delayed system”. Int JSoft ComputEng; Vol. 1(2): pp. 2231–307, 2012.
XIV.Rama Reddy D, Sailaja M. “Stability region analysis of PID and series leading correction PID controllers for the time delay systems”.Int J EngSciTechnol, Vol. 4(07), pp. 1-8, 2012.
XV.Zhao YM, Xie WF, Tu XW. “Performance-based parameter tuning method of model-driven PID control systems”. ISA Trans, Vol.51(3): pp.393–9, 2012-15
XVI.Ziegler, J. G. and N. B. Nichols “Optimum settings for automatic controllers.” Transaction for the ASME, Vol.64, pp. 759–768,1942.
Soumyendu Bhattacharjee, Aishwarya Banerjee, Biswarup Neogi View Download